Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times) |
|
AC Current |
60.00/600.0/1000A, 3 ranges, 45Hz to 400Hz, True RMS
Basic accuracy: ±1.5% rdg. ±5dgt. (50/60Hz, filter ON) |
AC Voltage |
n/a |
Frequency |
n/a |
Crest factor |
2.8 and under (1.68 and under at 1000 A range) |
Filter function |
Cut off frequency 180Hz at filter ON (-3dB) |
Output function |
n/a |
Other function |
Flip-open mechanism (but still retaining proper orientation of display), Back light, Maximum value display, Data hold, Auto power off |
Display |
Digital LCD, max. 6000dgt., 91 segments
Display refresh rate: 1.1 sec or higher |
Power supply |
Coin type lithium battery (CR2032) × 1, Continuous use 20 hours |
Core jaw dia. |
φ 30mm (1.18 in) |
Dimensions, mass |
50mm (1.97 in) W × 136mm (5.35 in) H × 26mm (1.02 in) D, 115g (4.1 oz) |
Supplied accessories |
CARRYING CASE 9757 ×1, Strap ×1, Instruction manual ×1, Coin type
lithium battery (CR2032, for trial purposes only) ×1 |
|
|