Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times) |
|
AC Current |
10.00m/ 100.0m/ 1.000/ 10.00/ 200.0 A, 5 ranges, (40Hz to 2kHz, True RMS), Basic accuracy: ±1.0 % rdg. ±5 dgt. |
AC Voltage |
None |
Frequency measurement |
30.0 Hz to 1000 Hz, 2 ranges, Basic accuracy: ±0.3 % rdg. ±1 dgt. |
Crest factor |
2.5 and under (1.5 at 200 A range) |
Filter function |
Cut off frequency at filter ON: 180 Hz (-3dB) |
Signal Output |
REC output for current: DC 1 V/f.s. (2 V/f.s. at only 200 A range), response time: less than 200 ms.
MON output for current: AC 1 V/f.s. (2 V/f.s. at only 200 A range), 5 Hz to 15 kHz frequency band width (-3 dB) |
Other function |
Max./ Min./ Average value record, Data hold, Auto-power OFF |
Display |
LCD, max. 2000 dgt., Display refresh rate: 4 times/s at fast, 1 time/3 sec. at slow, and Bar graph display 4 times/s |
Power supply |
6F22 (Stacked manganese battery) ×1, Continuous use: 40 hours, or AC adapter 9445-02 |
Core jaw dia. |
φ 40 mm (1.57 in) |
Dimensions, mass |
62 mm (2.44 in) W × 225 mm (8.86 in) H × 39 mm (1.54 in) D, 400 g (14.1 oz) |
Supplied accessories |
CARRYING CASE 9399 ×1, Hand strap ×1, Stacked manganese battery (6F22) ×1, Instruction Manual ×1 |
|
|