| Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times) |
 |
| |
3288 |
3288-20 |
| DC Current |
100.0/ 1000 A, Basic accuracy: ±1.5 % rdg. ±5 dgt. |
| AC Current |
100.0/ 1000 A, (10 Hz to 500 Hz, Average rectified),
Basic accuracy: ±1.5 % rdg. ±5 dgt. |
100.0/ 1000 A, (10 Hz to 500 Hz, True RMS),
Basic accuracy: ±1.5 % rdg. ±5 dgt. |
| DC Voltage |
419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt. |
| AC Voltage |
4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to 500 Hz, Average rectified) |
4.4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to 500 Hz, True RMS) |
| Resistance |
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt. |
| Crest factor |
None |
3 and under (2 at 1000 A range, 1.5 at Voltage) |
| Other function |
Continuity: (50 Ω ±40 Ω) or less buzzer sounds, Data hold, Auto power save, Auto zero (DC A) |
| Display |
LCD, max. 4199 dgt., Display refresh rate: 2.5 times/s |
| Power supply |
Coin type lithium battery (CR2032) ×1, Continuous use 60 hours |
Coin type lithium battery (CR2032) ×1, Continuous use 35 hours |
| Core jaw dia. |
φ 35 mm (1.38 in) |
| Dimensions, mass |
57 mm (2.24 in) W × 180 mm (7.09 in) H × 16 mm (0.63 in) D, 150 g (5.3 oz) |
| Supplied accessories |
Instruction Manual ×1, TEST LEAD L9208 ×1, CARRYING CASE 9398 ×1 |
|
|