Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times) |
|
DC Current |
20.00/ 200.0 A, Basic accuracy: ±1.3 % rdg. ±3 dgt. |
AC Current |
20.00/ 200.0 A, (10 Hz to 2 kHz, True RMS),
Basic accuracy: ±1.3 % rdg. ±3 dgt. |
DC Voltage |
30.00 V to 600 V, 3 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. |
AC Voltage |
30.00 V to 600 V, 3 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. (10 to 1 kHz, True RMS) |
Crest factor |
2.5 and under (1.5 at 200 A, 1.7 at 600 V) |
Monitor, Analog output |
DC, or AC 1 V/ f.s., Level output, Waveform output: DC to 20 kHz Band-width (±3dB) |
Resistance, Continuity check |
None |
Frequency |
1.00 Hz to 1000 Hz, Basic accuracy: ±0.3 % rdg. ±1 dgt. |
Other function |
AC+DC mode, Maximum/ Minimum/ Average value record function, Data hold, Peak hold, Auto power off, Auto zero |
Display |
Display refresh rate: 4 times/s (at FAST), 1 time/3s (at SLOW), 4 times/s (bar graph) |
Power supply |
6F22 (Stacked manganese battery) ×1, Continuous use: 25 hours, or AC adapter 9445-02 |
Core jaw dia. |
φ33 mm (1.30 in) |
Dimensions, mass |
62 mm (2.44 in) W × 230 mm (9.06 in) H × 39 mm (1.54 in) D, 460 g (16.2 oz) |
Supplied accessories |
TEST LEAD L9207-10 ×1, CARRYING CASE 9399 ×1, Hand strap ×1, 6F22 (Stacked manganese battery) ×1, Instruction Manual ×1 |
|
|