| MODEL |
3165 |
3166 |
| Insulation Resistance |
| DC Test Voltage |
500V |
1000V |
Max. Effective
Scale Value |
1000MΩ |
2000MΩ |
| Mid-Scale Value |
20MΩ |
50MΩ |
First Effective
Measuring Range
Accuracy |
1~500MΩ |
2~1000MΩ |
| |±5% rdg |
Second Effective
Measuring Range
Accuracy |
0.5/1000MΩ |
1/2000MΩ |
| |±10% rdg |
| AC Voltage |
600V |
| Accuracy |
|±3% of full scale value |
| Withstand Voltage |
3700V AC for 1 minute |
| Power Source |
R6P (AA) (1.5V) × 4 |
| Dimensions |
90(L) × 137(W) × 40(D)mm |
| Weight |
330g approx. |
| Accessories |
7025 (Test leads)
9067 (Pouch for test lead)
Neck Strap
R6P (AA) × 4
Instruction Manual |
|
|
|