MODEL |
3165 |
3166 |
Insulation Resistance |
DC Test Voltage |
500V |
1000V |
Max. Effective
Scale Value |
1000MΩ |
2000MΩ |
Mid-Scale Value |
20MΩ |
50MΩ |
First Effective
Measuring Range
Accuracy |
1~500MΩ |
2~1000MΩ |
|±5% rdg |
Second Effective
Measuring Range
Accuracy |
0.5/1000MΩ |
1/2000MΩ |
|±10% rdg |
AC Voltage |
600V |
Accuracy |
|±3% of full scale value |
Withstand Voltage |
3700V AC for 1 minute |
Power Source |
R6P (AA) (1.5V) × 4 |
Dimensions |
90(L) × 137(W) × 40(D)mm |
Weight |
330g approx. |
Accessories |
7025 (Test leads)
9067 (Pouch for test lead)
Neck Strap
R6P (AA) × 4
Instruction Manual |
|
|
|