Insulation resistance (*): Accuracy is not guaranteed with setting of 250V or less |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rated voltage |
|
|
|
500V |
|
|
|
1000V |
|
|
|
2500V |
|
|
|
5000V |
|
|
|
10000V |
|
|
|
12000V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Max
measurement
value |
|
|
|
500GΩ |
|
|
|
1TΩ |
|
|
|
2.5TΩ |
|
|
|
5TΩ |
|
|
|
35TΩ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Accuracy |
|
|
|
400k~50GΩ
±5%rdg±3dgt
(*) |
|
|
|
800k~100GΩ
±5%rdg±3dgt |
|
|
|
2M~250GΩ
±5%rdg±3dgt |
|
|
|
4M~500GΩ
±5%rdg±3dgt |
|
|
|
8M~1TΩ
±5%rdg±3dgt |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
50G~500GΩ
±20%rdg
(*) |
|
|
|
100G~1TΩ
±20%rdg |
|
|
|
250G~2.5TΩ
±20%rdg |
|
|
|
500G~5TΩ
±20%rdg |
|
|
|
1T~10TΩ
±20%rdg |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10T~35TΩ
Values are displayed, but accuracy isn't guaranteed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Short circuit current |
|
|
|
Max 5.0mA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Load resistor to output rated voltage |
|
|
|
0.5MΩ or more |
|
|
|
1MΩ or more |
|
|
|
2.5MΩ or more |
|
|
|
5MΩ or more |
|
|
|
20MΩ or more |
|
|
|
24MΩ or more |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output voltage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rated voltage |
|
|
|
500V |
|
|
|
1000V |
|
|
|
2500V |
|
|
|
5000V |
|
|
|
10000V |
|
|
|
12000V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Monitor accuracy |
|
|
|
±10%±20V |
|
|
|
±10%±20V |
|
|
|
±10%±20V |
|
|
|
±10%±20V |
|
|
|
±10%±20V |
|
|
|
±10%±20V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Output accuracy |
|
|
|
0~+20% |
|
|
|
0~+10% |
|
|
|
0~+10% |
|
|
|
0~+10% |
|
|
|
-5~+5% |
|
|
|
-5~+5% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Selectable range |
|
|
|
50~600V
(in steps of 5V) |
|
|
|
610~1200V
(in steps of 10V) |
|
|
|
1225~3000V
(in steps of 25V) |
|
|
|
3050~6000V
(in steps of 50V) |
|
|
|
6100~
10000V
(in steps of 100V) |
|
|
|
10100~
12000V
(in steps of 100V) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Voltage measurement |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Measuring range |
|
|
|
DCV : ±30~±600V, ACV : 30~600V (50/60Hz) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Accuracy |
|
|
|
±2%rdg±3dgt |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Current measurement |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Measuring range |
|
|
|
0.00nA~2.40mA (Depending on the insulation resistance) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Capacitance measurement |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Measuring range |
|
|
|
5.0nF~50.0µF |
|
|
|
5.0nF~1.0µF
(display range: 5.0nF~50.0µF) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Accuracy |
|
|
|
±5%rdg±5dgt |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
General |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Withstand voltage |
|
|
|
AC8770V : between line terminal and enclosure / 5sec (50/60Hz)
AC6880V : between the measuring terminal and enclosure / 5sec (50/60Hz)
AC2330V : between the power connector and enclosure / 5sec (50/60Hz) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operating temperature & humidity range |
|
|
|
-10ºC~50ºC / |
Relative humidity 85% or less
(when operating with an external power supply, no condensation) |
0ºC~40ºC / |
Relative humidity 85% or less
(when operating with battery, no condensation) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Storage temperature & humidity range |
|
|
|
-20ºC~60ºC / Relative humidity 75% or less (no condensation) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Applicable standards |
|
|
|
IEC 61010-1 CAT.IV 600V Pollution degree 2,
IEC 61010-031, IEC 61326, IEC 60529 (IP64): with the lid closed. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power source |
|
|
|
Rechargeable Lead storage battery (12V)*
Charging time: approx. 8 hours / AC Power supply (100V~240V, 50/60Hz)
* Continuous measuring time:
approx. 4 hours |
(a load of 100MΩ at the Insulation resistance 12000V Range.) |
|
approx. 2 hours |
(Max current consumption in range while rated currents are maintained.) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dimension |
|
|
|
330 (L) × 410 (W) × 180 (D) mm *Instrument and Hard case |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Weight |
|
|
|
9kg approx. (including battery) *Instrument and Hard case |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Accessories |
|
|
|
7170 (Main cord), 7224A (Earth cord), 7225A (Guard cord), 7226A (Line probe),
7227A (Line probe with alligator clip), 8029 (Extension prod),
8212-USB-W (USB adaptor with KEW Windows (Software)),
Instruction manual, Calibration Certificate |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Optional |
|
|
|
7254 (Longer Line probe with alligator clip) |