Basic specifications (Accuracy guaranteed for 1 year) |
|
DC Voltage |
600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt. |
AC Voltage 40 to 500 Hz |
6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz - 1 kHz
Basic accuracy: ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Resistance |
600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±5 dgt. |
DC Current |
N/A |
AC Current, 40 to 500 Hz |
N/A |
AC Current (use with the Clamp on probe) 45 to 1k Hz |
10.00 A to 1000 A, 7 ranges
Add the Clamp on probe accuracy to Basic accuracy: ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Temperature (use with DT4910) |
N/A |
Voltage Detection |
80 V to 600 V AC |
C (capacitance) |
1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
Frequency |
AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges, 99.99 kHz (only for AC V)
Basic accuracy: ±0.1 % rdg. ±1 dgt. |
Continuity Check |
Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
Diode test |
Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
Other functions |
Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option) |
Display |
Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
Display refresh rates |
5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s ) |
Power supply |
LR03 alkaline batteries ×4, Continuous use: 130 hours (back light OFF) |
Dimensions and mass |
84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (with batteries and holster) |
Accessories |
TEST LEAD L9207-10 ×1, Holster ×1, Instruction Manual ×1, LR03 Alkaline Battery ×4 |
|
|