RPE 20Ω Protective Conductor Resistance Test |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Measuring range |
 |
 |
 |
0 ~ 15.00Ω |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Resolution of measurement |
 |
 |
 |
10mΩ |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Open circuit voltage |
 |
 |
 |
< AC 12V |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Measuring current |
 |
 |
 |
10A AC nominal value |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Accuracy |
 |
 |
 |
±3%rdg±5dgt |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
RINS 200MΩ Insulation Resistance |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Rating |
 |
 |
 |
250V/20MΩ |
 |
 |
 |
500V/20MΩ |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Measuring range |
 |
 |
 |
0 ~ 19.99Ω |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Resolution of measurement |
 |
 |
 |
10kΩ |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Output voltage |
 |
 |
 |
250V DC (+20%/-10%) @1MΩ |
 |
 |
 |
500V DC (+20%/-10%) @1MΩ |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Short circuit current |
 |
 |
 |
2.5mA DC or less |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Accuracy |
 |
 |
 |
±2%rdg±3dgt |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Leakage Current Test |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Measuring range |
 |
 |
 |
AC 0.1 ~ 19.99mA |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Resolution of measurement |
 |
 |
 |
0.01mA |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Examination time |
 |
 |
 |
Max 15 seconds |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Accuracy |
 |
 |
 |
±3%rdg±5dgt |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
AC VOLT Mains Voltage Check |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Measuring range |
 |
 |
 |
207 ~ 264V |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Resolution of measurement |
 |
 |
 |
1V |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Accuracy |
 |
 |
 |
±2%rdg±3dgt |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Supply voltage |
 |
 |
 |
240V±10% |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Frequency |
 |
 |
 |
50Hz±1% |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Applicable standards |
 |
 |
 |
IEC 61010-1 CAT.III 300V Pollution Degree2
IEC 61326-1 (EMC) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions |
 |
 |
 |
185 (L) × 167 (W) × 89 (D) mm |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
1.2kg (only the instrument body) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Accessories |
 |
 |
 |
7123 (Power cord [AU])
7129A (Test leads with alligator clip)
7161A (Flat test prod [black])
7140 (Adapter for exntesion cord)
9147 (Cord case)
9121 (Shoulder strap)
Instruction manual |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Optional |
 |
 |
 |
7121B (Distribution board test leads) |