Loop Impedance Ranges |
20/200/2000Ω |
Loop Impedance
Accuracy |
|±2%rdg±4dgt |
AC Test Current |
20Ω 25A
200Ω 2.3A
2000Ω 15mA |
AC Test Period |
20Ω (20ms)
200Ω (40ms)
2000Ω (280ms) |
PSC Ranges |
200A (2.3A 40ms)
2000A (25A 20ms)
20kA (25A 20ms) |
PSC Ranges Accuracy |
Consider accuracy of Loop impedance |
Voltage |
110V-260V ±2%rdg±4dgt |
Operating Voltage |
230V+10% -15% (195V~253V) 50Hz |
Safety Standard |
IEC 61010-1 CAT.III 300V
IEC 61557-1,-3
IEC 61010-2-031 Pollution Degree 2 |
IP Rating |
IEC 60529-IP54 |
Dimensions |
185(L) × 167(W) × 89(D)mm |
Weight |
750g approx. |
Accessories |
Molded plug test leads
7121B (Simplified measurement probe)
Pouch for test leads
Shoulder Strap
Instruction Manual |