MODEL 4106
Giá bán: Liên hệ
Tình trạng: Đang có hàng
Thông tin chi tiết
 
Function Range Resolution Measuring range Accuracy
Earth resistance
Re
(Rg at
ρ measurement)
0.001Ω 0.03~2.099Ω |±2%rdg±0.03Ω
20Ω 0.01Ω 0.03~20.99Ω |±2%rdg±5dgt (*1)
200Ω 0.1Ω 0.3~209.9Ω
2000Ω 3~2099Ω
20kΩ 10Ω 0.03~20.99kΩ
200kΩ 100Ω 3~209.9kΩ
Auxiliary earth resistance
Rh, Rs
      8% of Re+Rh+Rs
Earth resistivity
ρ
0.1Ω•m~1Ω•m
Autoranging
0.2~395.6Ω•m ρ=2×π×a×Rg (*2)
20Ω 0.2~3956Ω•m
200Ω 20~39.56kΩ•m
2000Ω 0.2~395.6kΩ•m
20kΩ 2.0~1999kΩ•m
200kΩ
Series interference voltage
Ust (A.C only) (*3)
50V 0.1V 0~50.9Vrms |±2%rdg±2dgt (50/60Hz)
|±3%rdg±2dgt (40~500Hz)
Frequency
Fst
Autoranging 0.1Hz
1Hz
40Hz~500Hz |±1%rdg±2dgt
Measuring method Earth resistance: Fall-of-potential method (currents and voltages measured via the Probes)
Measurement method of Earth Resistivity (ρ): Wenner 4-pole method
Series interference voltage (earth voltage): RMS Rectifier (between the E-S Terminals)
Memory capacity 800 data
Communication Interface Model 8212-USB Optical Adaptor
LCD Dot-matrix 192×64 monochrome
Over-range Indication "OL"
Overload Protection between E-S(P) and between E-H(C) terminals AC280V / 10 sec.
Withstand voltage between the electrical circuit and enclosure AC3540V(50/60Hz) / 5 sec.
Applicable standards IEC 61010-1 CAT.III 300V, CAT.IV 150V Pollution degree 2
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54)
Power source DC12V : sizeAA manganese dry battery (R6P) × 8
(Auto power off: approx. 5 minutes)
Dimensions 167(L) × 185(W) × 89(D) mm
Weight approx. 900g (including batteries)
Accessories 7229A (Earth precision measurement),
7238A (Simplified measurement test leads),
8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),
8200-04 (Cord reel [4 pcs])×1 set,
8212-USB (USB adaptor with "KEW Report(Software)"),
9121 (Shoulder strap),
9125 (Carrying case),
R6P×8, Instruction manual, Calibration certificate
Optional 8212-RS232C (RS232C adaptor with "KEW Report(Software)")
(*1) Auxiliary earth resistance is 100Ω with Rk correction
(*2) Depending on the measured Rg. Interval [a] between auxiliary earth spikes is 1.0~30.0m
(*3) This instrument is NOT designed to measure line voltages on commercial powers.